Educerie · AP · Chemistry
AP Chemistry 4.6
Introduction to Titration
How do we describe, represent and predict the changes substances undergo, and how much of each substance is involved?
What you will learn
- Understand that titration finds the amount of an analyte using a titrant of known concentration
- Know the difference between the equivalence point and the endpoint
- Know that at equivalence the analyte is exactly used up according to the mole ratio
- Understand how procedure errors change the calculated result
You must be able to
- Calculate the concentration of an analyte from titration data
- Use the mole ratio for a 1 to 2 reaction
- State the difference between the equivalence point and the endpoint
- Sketch and read a strong acid and strong base titration curve with scales
- Predict whether an error makes the result too high or too low
- Find the concentration of a titrant from a primary standard
In the exam. Section I multiple choice: a titration calculation, a data table of buret readings, a procedure item (why the buret is rinsed with the titrant), or the effect of an error on the calculated concentration. In Section II, a titration can appear in a long question: a molarity from a volume at the equivalence point, a graph of pH against volume to sketch or read, and a reasoned prediction of what changes.
1The apparatus and what each part does
- Buret = a long graduated tube with a tap, holding the titrant. It reads volume added to .
- Pipet or volumetric flask = glassware for a fixed, accurate volume of analyte. A pipet delivers one volume, such as .
- Conical flask = holds the analyte, with a few drops of indicator. Swirl it as the titrant goes in.
- Indicator = a substance that changes colour near the equivalence point. For a strong acid with a strong base, phenolphthalein turns from colourless to pink.
Two terms that students mix up:
- Equivalence point = a fact about amounts. The moles of titrant added are exactly what the equation needs to react with all the analyte.
- Endpoint = something you see: the colour change. The endpoint is chosen to fall at the equivalence point, as nearly as it can.
2Using the data
At the equivalence point, for a reaction with a mole ratio, the moles of titrant added equal the moles that the analyte needs.
For a 1 to 1 reaction:
For any ratio, go through moles instead.
- Moles of titrant , with in litres.
- Moles of analyte from the mole ratio of the equation.
- Divide by the volume of analyte, in litres.
Worked example 1: a 1 to 1 reaction. of hydrochloric acid needs of sodium hydroxide.
Worked example 2: a 1 to 2 reaction. of sulfuric acid needs of sodium hydroxide. Both protons are neutralised.
Worked example 3: finding the titrant's concentration. A pure solid acid is used to find the molarity of a sodium hydroxide solution. Potassium hydrogen phthalate (KHP, a one-proton acid, ) is a common choice. A mass of needs of the base.
3The titration curve
A titration curve plots the pH of the flask against the volume of titrant added. For a strong acid titrated with a strong base, its shape is the same each time.
Figure 1 is of titrated with . Read it in four parts.
- At the start: . The acid is strong acid.
- Before the equivalence point: the pH rises slowly. Base is added and acid is used up, so the remaining acid is more dilute.
- At the equivalence point, , the curve rises almost vertically, through . The flask holds only sodium chloride and water, which is neutral.
- After the equivalence point: the pH levels off at a high value. The extra base is now in excess.
The steep part is why an indicator works. The pH jumps from about 3.7 to 10.3 for a change of , from to , so a single drop swings the indicator's colour.
To draw a curve in the exam:
- Label the axes: pH on the vertical, volume of titrant added (in mL) on the horizontal.
- Start at the pH of the acid (1.00 here).
- Mark the equivalence point at its volume, and put the steep rise through it.
- Level off at the pH of the excess base.
Find the equivalence volume with the mole ratio. Here of acid, so of base.
Example: if the same acid were , twice as much base would be needed in total. The equivalence point moves to of the same base, and the curve starts at .
4Technique and sources of error
Good technique makes the volumes true. The exam asks why each step is done.
- Rinse the buret with the titrant before filling. Water left in it would dilute the titrant.
- Rinse the pipet with the analyte. Water left in it would dilute the analyte.
- The conical flask can be wet with water. Water adds no moles of analyte, so it does not change the result.
- Remove air from the buret tip before the first reading. A bubble that leaves during the titration makes the volume read too large.
- Add titrant a drop at a time near the endpoint, and read the meniscus to the nearest .
- Repeat until two or more results agree closely.
How an error changes the result:
| Error | Effect on the volume of titrant used | Effect on the calculated analyte concentration |
|---|---|---|
| Buret rinsed with water, not titrant | More titrant is needed, because it is diluted | Too high |
| Pipet rinsed with water, not analyte | Less titrant is needed, because the analyte is diluted | Too low |
| Air bubble in the buret tip that leaves | The reading is larger than the liquid delivered | Too high |
| Endpoint passed (too much titrant) | Larger volume | Too high |
| Conical flask rinsed with water | No change | No change |
Practice questions
30 questions on this note, from easy to hard. Each one you get right lights a star of this topic's constellation.